1.
Q: Can I use Rondo 308 Furring Channel in a Fire Rated ceiling?
A: No, only systems using 129 Furring Channel have been fire tested.
2.
Q: Can I use Rondo 125 Top Cross Rail for a fire rated ceiling?
A: Yes, but only to comply with specific plasterboard manufacturer’s tests.
3.
Q: Can I use Rondo 167 Side-mounted Top Cross Rail Suspension Clip to suspend 2 layers of plasterboard?
A: No, Rondo only recommends Rondo 167 as being capable of supporting a single layer of plasterboard (13mm maximum)
4.
Q: Is there a wall anchor clip for Rondo 301 Batten?
A: No, 301 Batten should only be used in a ceiling application.
5.
Q: Do you have a wall anchor clip for Rondo 333 furring channel?
A: No, Rondo 333 Furring Channel must be directly fixed to the substrate
6.
Q: Can I nail or screw fix Rondo 301 Batten to the underside of joists in a double storey application?
A: No, in any double storey application clips must be used and batten must have a minimum clearance of 1-2mm from the underside of the joist.
7.
Q: When should I use noggings?
A: Noggings provide support to the wall studs and prevent twisting of the studs when fitting to lining boards. For more information go to page 10 of the Rondo Steel Stud Technical Manual
8.
Q: Can I attach shelves to a Rondo staggered Stud Wall Framing System?
A: No, shelf loading is not permitted on the tabulated wall heights. For more information on Staggered Wall Studs, refer to page 12 of the Rondo Steel Stud Wall Framing Technical Manual.
9.
Q: Can I drill or cut out extra holes in Rondo stud to provide for other services?
A: Yes you can, with limitations - additional service holes should be positioned as close as practical to the centre line of the stud. For more information, refer to page 19, figure 33 in the Rondo Steel Stud Wall Framing System Technical Manual for details.
10.
Q: When should I use a Control Joint?
A: Control Joints must be used when continuous plasterboard wall or ceiling linings exceed 12metres in any direction and to the requirements of the board manufacturer. Fibre cement lining applications may vary.
11.
Q: What size drill bit should be used when fixing the MACS6 Anchor Bolt supplied with A239 Furring Channel Clip and A124 Top Cross Rail Clip assemblies?
A: The drill size is 6mm
12.
Q: Where do I find the maximum span details for Rondo 301 batten?
A: You can find the span tables on page 28 in the Rondo KEY-LOCK® Concealed Suspended Ceiling System Technical Manual.
13.
Q: What is the maximum span for continuous Rondo 301 Batten with 10mm plasterboard and 13mm plasterboard in typical N2 wind load areas?
A: 1200m for both at 450 & 600 spacing of Batten, for more information read page 28 of the Rondo
KEY-LOCK® Suspended Ceiling System Technical Manual.
14.
Q: What does Single and Continuous Span mean?
A: Single span is when a single member is supported at each end only and Continuous Span is where a single member is supported at three or more points along its length. For more information refer to the Rondo KEY-LOCK® Suspended Ceiling System Technical Manual.
15.
Q: What are the correct fasteners for Rondo 301 batten (hardwood/softwood)?
A: In both hardwood and softwood 2.8mm Annular Ring Shanked Nails can be used or Wafer Head screws. For full details refer to Table 4, page 19 of the Rondo KEY-LOCK Concealed Suspended Ceiling System Technical Manual.
16.
Q: Can Rondo 301 Batten be used in a commercial application?
A: 301 Batten is designed for domestic use. Rondo 308 16mm or Rondo 129 28mm Furring Channels are appropriate for commercial applications either direct fixed or suspended. Refer to the Rondo KEY-LOCK® technical Manual for more information.
17.
Q: What is the correct internal backing angle to use in wet rooms to comply with AS3740-2002?
A: The correct internal backing angle to use is Rondo P40 Flashing Angle details of which can be found on page 11 in the Rondo EXANGLE® Drywall Finishing Sections Technical Manual.
18.
Q: Can I use Rondo External Corner Beads PX1 and P01 in exterior applications?
A: No, they are designed for interior applications only.
19.
Q: What sections can I use for Masonry Wall Battening?
A: From the Rondo KEY-LOCK® Ceiling System range, 333 Furring Channel, 308 Furring Channel and 129 Furring Channel are appropriate. Rondo 333 Furring Channel is fixed directly whereas 308 and 129 Furring Channels can only be fixed with specific Rondo clips. For more information on Masonry Wall Battens, read page 20 of the Rondo KEY-LOCK® Ceiling System Technical Manual.
20.
Q: Do you have a specific External Suspended Ceiling System?
A: Yes, our KEY-LOCK® Suspended Ceiling System can be used for this purpose in most situations, however more detailed information can be found on page 12 of the Rondo KEY-LOCK® Technical Manual.
21.
Q: What are the maximum allowable ceiling weights for a Rondo suspended plasterboard ceiling?
A: Allowable ceiling weights vary according to the KEY-LOCK Suspended Ceiling System components used and their spacings. Full details are available by referring to the Load Tables in the Rondo KEY-LOCK® Technical Manual between pages 32 and 34.
22.
Q: Are Rondo Studs fire-rated?
A: Yes, all Rondo Steel Studs have been tested by the leading plasterboard manufacturers and incorporated in their fire rated system designs, available in their technical literature. For more details on Rondo Steel Studs, view Rondo Steel Stud Wall Framing Technical Manual.
23.
Q: In what application should a Rondo deflection head track be used?
A: Rondo Deflection Head Track should be used when wall construction is a concrete Slab joined to a concrete Slab with movement. For more details, view Rondo Steel Stud Wall Framing Technical Manual.
24.
Q: Do you have a clip to suspend a ceiling system from the lip of a “Z” Purlin or “C” Channel Purlin?
A: No, it is not recommended to do so as per the Australian Standard 2785.2000. Appropriate installation details for suspending from steel purlins can be found on page 7 of the Rondo KEY-LOCK® Suspended Ceiling System Technical Manual.
25.
Q: Can Rondo Steel Studs be boxed?
A: Yes normally, with the exception of Rondo 1.15 bmt studs. For a more detailed explanation refer to Page 7 of the Rondo Steel Stud Wall Framing Technical Manual.
26.
Q: Do I need to box Rondo Studs around window and door openings?
A: Yes, Rondo studs should be boxed around window and door openings; more details can be found on page 18 Rondo Steel Stud and Track Technical Manual.
27.
Q: Where do I find information on maximum wall heights for Rondo Steel Studs?
A: Wall height tables can be found on pages 24 and 25 Rondo Steel Stud and Track Technical Manual.
28.
Q: What quantity of Rondo Main Tee and Cross Tee cartons equates to 100m2 of a typical 1200 x 600 ceiling grid?
A: 1 box of Main Tee and 2 Boxes of Cross Tee equates to 100m2. For more information, see Rondo DUO® Exposed Grid Ceiling System Technical Manual.
29.
Q: Do you have a Rondo Acoustic or Sound rated stud?
A: Yes, Rondo has an acoustic stud known as the Rondo Quiet Stud™. For more details, refer to pages 20 to 23 of the Rondo QUIET STUD™ Technical Manual.
30.
Q: Do you have PVC beads that can be used in external applications?
A: Yes, the Rondo EXTREME® range of PVC beads includes profiles suitable for both external and internal applications. For more details, view the Rondo EXTREME® PVC Bead Technical Manual.